PENGARUH VARIASI DIAMETER PIPA INPUT DAN PIPA OUTPUT TERHADAP KINERJA POMPA HIDRAM

  • budi santoso wibowo Universitas Bangka Belitug

Abstract

Bangka Belitung Province is one of the provinces that have a vast potential of agricultural land, with the potential for abundant water resources in an area that is often in contradiction with the conditions in which some regions still lack water. Often the source of water is under the location of settlements or agricultural land, so it is difficult to use it. The use of electric/diesel pumps has significant cost consequences, as some farmers do use diesel pumps to irrigate their farm fields from rivers that are nearby. One technology that is simple and inexpensive to use is the use of a hydram pump. The methodology in this study is that the hydram pump drive is derived from the impact of water entering the pump through a pipe that depends on the flow of flow entering the pump. This study discusses the performance of hydram pumps on variations in the diameter of the Input pipe and Output pipe. The results of the study that the greatest efficiency of hydram pump for discharge of 8 liters/minute is in the variation of the diameter of the Input pipe 1 inch and the Output pipe 1½ inches is 9.5%, while the lowest efficiency in the variation of the Input pipe diameter is 1½ inches and the Output pipe 1½ inches is 6, 2%. The results of the study found that the larger the diameter of the Input pipe and the smaller the diameter of the Output pipe, the greater the efficiency produced at the hydram pump.

Downloads

Download data is not yet available.

References

[1] Mietra Anggara, dkk.2013. Pengaruh Variasi Panjang Pipa Masuk (Drive Pipe) dan Beban Katup Buang (Waste Valve) Terhadap Efisiensi Pompa Hidram. Volume 5. No 2

[2] Shodiqin. 2015. Variasi Volume Tabung Tekan: Terhadap Kinerja Pompa Hidram. Jurusan Teknik Mesin Universitas Muhammadiyah Surakarta

[3] Ageng Yuwono, Aji (2015) Pengaruh Variasi Diameter Pipa Inlet Terhadap Debit Dan Head Pada Pompa Hidram. Diploma Thesis, Universitas Muhammadiyah Surakarta.

[4] Sulthoni, M. (2011). Pengaruh Diameter Pipa Inlet Terhadap Debit Pemompaan Pompa Hidram.Jurnal Semantic Scholar

[5] Hasan, M. Thaib. Dkk. 2014. Pengaruh Panjang Pipa Keluaran Terhadap Kinerja Pompa Hidraulic Ram Pump (Hydram). Jurnal Ilmiah Jurutera Volume 01 No. 02 (11.2014) 001-005
Published
2019-10-02
How to Cite
wibowo, budi. (2019). PENGARUH VARIASI DIAMETER PIPA INPUT DAN PIPA OUTPUT TERHADAP KINERJA POMPA HIDRAM. Machine : Jurnal Teknik Mesin, 5(2), 41-44. https://doi.org/10.33019/jm.v5i2.1366
Abstract viewed = 1349 times
PDF (Bahasa Indonesia) downloaded = 528 times